pH Meters for the Laboratory Bench
Calibration Check pH Meters
After every calibration, these "cal-check" pH meters
display both the condition and the response of the connected electrode. Along with all of the advanced features you
expect such as GLP (good laboratory practice), computer ports and more, this is another first from Hanna
Instruments. These cal-check pH meters should be standard laboratory
equipment. This page shows six different pH bench meters with the
calibration check feature. Some have built in printers and Ion Selective
Electrode (ISE) reading capabilities.
 
Key Features:
- Electrode holder included with pH meter
- Log on demand
- Recall logged data
- GLP (Good Laboratory Practice)
- Cal-Check: electrode checking for
condition & response
- Calibration Alarm Time out: 1 to 7 days
or disabled
- Automatic temperature compensation
- Automatic buffers
- Computer interface (RS-232 optically
isolated)
- Warranty: 5 years for laboratory equipment
- Two or three decimal place accuracy
- pH and mV ranges
pH Meters: Bench Models
HI 110,
HI 111, HI 112, HI 113 pH meters
The
continuing innovation of Hanna Instruments pH meters is shown here. The
buttons on the left take you to a whole series of different pH meters designed
for a variety of applications.
The pH meter pictured is model number HI 111 which is
one of a number of bench meters manufactured by Hanna Instruments. Other
models both more basic and more sophisticated are shown on other pages (see
navigation tabs on left). MBH Engineering can guide you based upon your
requirements for lab equipment. Detailed specification sheets can be
emailed to you showing the exact model needed.
The model HI 111 features GLP (Good Laboratory
Practice) data collection showing: offset, slope, date, time of last
calibration. In addition to calibration at the standard 4, 6.86, 7, 9.18
and 10 buffer values, the user can also calibrate at two more custom defined
points. The unit features ATC, opto-isolated RS-232 output and a mV
scale for more measurements. Accessories not included with this
instruments are an electrode holder stand (pictured), PC software and a serial
cable as well as buffer, storage and cleaning solutions. HI 113 has all
the same features but with two or three digit measurement of pH as opposed to
the the model HI 111 which is limited to pH measurement at 0.01 accuracy.
The models HI 110 and HI 112 are missing the mV scale which can be very
helpful in electrode diagnostics. These instruments can take advantage
of Hanna's technical buffers which are available at pH values from 1.00, 2.00,
3.00 etc. to 13.00. When you need accuracy, Hanna's pH meters and
electrodes perform. Most people are surprised when they find out the
Hanna is the largest manufacturer of pH instruments and electrodes in the
world. They continue to innovate in the field of pH measurement and lab
equipment. We are proud to be a representative and stocking distributor
for Hanna Instruments for the past fifteen years.
HI 250, HI 251, HI 253, HI 254
Step up to the 250 series pH meters. This
quartet of meters all sport an RS-232 serial port for computer connectivity,
automatic memorized buffers and pH range up to 16.00/16.000. Other
standard features include: an electrode stand,
refillable glass electrode, temperature sensor and 12Vdc adaptor.
Differences between the models are shown on the table below but can be
summarized: HI 250 pH only, HI 251 pH/mV and the higher
resolution models: HI 254 pH/mV, HI 253 pH/mV and ISE (ion
selective electrode measurement). The meters look like the 110 series
shown above.
| |
HI 250 |
HI 251 |
|
HI 253 |
HI 254 |
|
Resolution |
0.01 pH |
0.01 pH |
|
0.001 pH |
0.001 pH |
|
Resolution, ORP |
|
0.1mV |
|
0.1mV |
0.1mV |
|
Resolution |
0.1ºC |
0.1ºC |
|
0.1ºC |
0.1ºC |
|
Resolution |
|
|
|
0.001 mg/l |
|
|
Calibration |
1-3pts |
1-3pts |
|
1-3pts |
1-5pts |
|
Calibration |
|
|
|
1 or 2 ISE |
|
|
Buffers |
5 std |
5 std |
|
5 std |
5 std + 2 |
|
GLP |
yes |
yes |
|
yes |
yes |
|
ATC |
yes |
yes |
|
yes |
yes |
Specifications and product details: HI 221 and HI 223
Applications:
- Quality Assurance/ Quality Control
Laboratories
- Production Labs
- Food and Beverage Labs
- Breweries
- General purpose pH meter for WWTP
We suggest you read the "white paper" on
laboratory equipment reprinted from American Laboratory News "Improvements in pH
Measurements." This technical paper explores the problems which are
typical for pH meter measurements. In particular the paper discusses the
reasons pH meters can provide readings which are inaccurate. pH meter
users can be unaware of the issue and then rely on readings which are incorrect.
The article goes on to explain how to overcome these issues.

More Calibration Check pH meters:
The 120 series pH meters from Hanna Instruments also
are equipped with the "cal-check" feature.
Datalogging pH Meters with
Cal Check™
HI 120 and HI 121
* Measure pH, mV, Temp
and Selective Ion (HI 121 only)

*
Calibration Check™ Feature
* GLP Compliant
* Selectable
accuracy 0.01 or 0.001pH
When pH measurements need to be performed, the
calibration phase is very important. It is often necessary for the user to
measure extreme pH values or values far from standard calibration buffers. HI
120 and HI 121 can offer help in these situations, thanks to automatic
calibration in up to 5 points. Users can select each point from among the 7
factory stored values and up to 2 more values manually entered for specific
applications. Moreover, thanks to Calibration Checktm, good
calibration results can be easily viewed directly on the display with the
percentage information regarding pH electrode condition and response. Both pH meters
are in compliance with GLP. HI 120 can also perform ORP measurements and the HI
121 adds ion-selective measurement capability as well. Both of these pH meters
store data that can be easily downloaded to a PC thanks to an RS232 port and
optional HI 92000 software.
HI 120 is supplied complete with HI 1131P pH electrode, HI 7662-T temperature
probe, pH 4 and pH 7 buffers, electrolyte solution, 12 Vdc power adapter and
instructions. HI 121 is supplied complete with HI 1131P pH electrode, HI 7662-T
temperature probe, pH 4 and pH 7 buffers, electrolyte solution, 12 Vdc power
adapter and instructions.
|
Specifications: |
|
|
|
Range pH |
|
-2.00 to 16.00 pH / -2.000 to 16.000 pH |
|
Range mV |
|
±999.9 and ±2000 mV |
|
Range
Selective Ions (HI 121 only) |
|
0.001 to 19999 ppm |
|
Range Temp |
|
-20.0 to 120.0°C |
|
Resolution
pH |
|
0.01 pH / 0.001 pH |
|
Resolution
mV |
|
0.1 mV / 1 mV |
|
Resolution
Selective Ions (HI 121 only) |
|
0.001 / 0.01 / 0.1 / 1 ppm |
|
Resolution
Temp |
|
0.1°C |
|
Accuracy
(@20°C/68°F) pH |
|
±0.01 pH / ±0.002 pH |
|
Accuracy
(@20°C/68°F) mV |
|
±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV)
/ ±1 mV (±2000 mV) |
|
Accuracy
(@20°C/68°F) Selective Ions (HI 121 only) |
|
±0.5% f.s. |
|
Accuracy
(@20°C/68°F) Temp |
|
±0.4°C |
|
BNC Inputs |
|
1 for pH electrode + 1 for ISE electrode
(HI 121 only) |
|
Calibration
Check |
|
status of electrode condition and response
time, status of the buffer solutions during calibration |
|
Relative mV
Offset |
|
±2000 mV |
|
pH
Calibration |
|
automatic, up to 5 points with 7 memorized
values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers |
|
ISE
Calibration (HI 121 only) |
|
automatic, 1 or 2 point with 5 memorized
values (0.1, 1, 10,100, 1000 ppm) |
|
Temp.
Compensation |
|
automatic or manual, -20.0 to 120°C (-4 to
248°F) |
|
pH Electrode |
|
HI 1131P, glass body, refillable, BNC +
pin connectors, 1 m cable (included) |
|
Temp. Probe |
|
HI 7662-T with 1 m cable (included) |
|
Input
Impedance |
|
1012 Ohm |
|
Log-on-demand |
|
50 samples (HI 120), 100 samples (HI 121) |
|
Auto Data
Logging |
|
1000 samples (HI 120), 2000 samples (HI
121) |
|
PC
Connection |
|
RS232 serial port, optoisolated |
|
Power Supply |
|
12 Vdc adapter (included) |
|
Environment |
|
0 to 50°C (32 to 122°F); RH max 95% |
|
Dimensions |
|
280 x 203 x 84 mm |
|
Weight |
|
1.8 kg (4.0 lb.) |

pH/Selective Ion Meters with
Built in Printer:
HI 122 and HI 123
-
Suited
for Many Applications
-
Calibration
Check™ Feature
-
Built-in Printer
-
Up to five calibration points including custom values
-
Selective accuracy: 0.01 or 0.001pH
HI 122 and HI 123 are strong additions to the HANNA instruments®
family of professional pH meters. These pH meters offer all the latest features and
built-in printer. Besides basic functions, like optional higher resolution and
automatic temperature compensation, they are provided with Hanna's Calibration
Check™ system for electrode calibration evaluation. The combination
of this option with the ability to calculate a calibration curve in 5 points
(from 7 stored plus 2 custom values), make these products suitable for any kind
of application, both with neutral pH, and with very alkaline pH values. Both
meters adhere to Good Laboratory Practices and can store data and measurements
of each calibration to be printed directly or downloaded to a PC through the
RS232 port. HI 123 can also measure specific ions directly in ppm. Calibration
is still fast and easy, in 1 or 2 points from among 5 standard memorized
buffers.
HI 122 is supplied complete with HI 1131P pH electrode, HI 7662-T temperature
probe, pH 4 and pH 7 buffers, electrolyte solution, 5 paper rolls, 12 Vdc power
adapter and instructions. HI 123 is supplied complete with HI 1131P pH
probe, HI 7662-T temperature probe, pH 4 and pH 7 buffers, electrolyte
solution, 5 paper rolls, 12 Vdc power adapter and instructions.

|
Specifications: |
|
|
|
Range pH |
|
-2.00 to 16.00 pH / -2.000 to 16.000 pH |
|
Range mV |
|
±999.9 and ±2000 mV |
|
Range
Selective Ions (HI 123 only) |
|
0.001 to 19999 ppm |
|
Range Temp |
|
-20.0 to 120.0°C |
|
Resolution
pH |
|
0.01 pH / 0.001 pH |
|
Resolution
mV |
|
0.1 mV / 1 mV |
|
Resolution
Selective Ions (HI 123 only) |
|
0.001 / 0.01 / 0.1 / 1 ppm |
|
Resolution
Temp |
|
0.1°C |
|
Accuracy
(@20°C/68°F) pH |
|
±0.01 pH / ±0.002 pH |
|
Accuracy
(@20°C/68°F) mV |
|
±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV)
/ ±1 mV (±2000 mV) |
|
Accuracy
(@20°C/68°F) Selective Ions (HI 123 only) |
|
±0.5% full scale |
|
Accuracy
(@20°C/68°F) Temp |
|
±0.4°C |
|
BNC Inputs |
|
1 for pH electrode + 1 for ISE electrode
(HI 123 only) |
|
Calibration
Check |
|
status of electrode condition and response
time, status of the buffer solutions during calibration |
|
Relative mV
Offset |
|
±2000 mV |
|
pH
Calibration (HI 123 only) |
|
automatic, up to 5 points with 7 memorized
values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers |
|
ISE
Calibration (HI 123 only) |
|
automatic, 1 or 2 point with 5 memorized
values 0.1, 1, 10,100, 1000 ppm) |
|
Temp.
Compensation |
|
automatic or manual, -20.0 to 120°C (-4 to
248°F) |
|
pH Electrode |
|
HI 1131P, glass body, refillable, BNC +
pin connectors, 1 m cable (included) |
|
Temp. Probe |
|
HI 7662-T with 1 m cable (included) |
|
Input
Impedance |
|
1012 Ohm |
|
Log-on-demand |
|
50 samples (HI 122), 100 samples (HI 123) |
|
Auto Data
Logging |
|
1000 samples (HI 122), 2000 samples (HI
123) |
|
PC
Connection |
|
RS232 serial port, opto-isolated |
|
Printer |
|
built-in, with 44 mm plain paper |
|
Power Supply |
|
12 Vdc adapter (included) |
|
Environment |
|
0 to 50°C (32 to 122°F); RH max 95% |
|
Dimensions |
|
280 x 203 x 84 mm |
|
Weight |
|
1.9 kg (4.2 lb.)
|
|
|
|
|
|